Suspended Solids Transmitter
SS312-01-ANALOG-3
Suspended Solids Transmitter
Product Highlights
• Integrated self-cleaning system reduces biofouling.
• Modulated light reduces visible-light interference.
• Automatic temperature compensation.
• 4–20 mA, 0–5 V or 0–10 V output; select one.
• IP68 probe and IP65 conversion module housing.
• Modulated light reduces visible-light interference.
• Automatic temperature compensation.
• 4–20 mA, 0–5 V or 0–10 V output; select one.
• IP68 probe and IP65 conversion module housing.
Product Overview
The SpeSense SS312-01-ANALOG Suspended Solids Transmitter is designed for continuous suspended solids measurement in wastewater treatment and industrial process applications. Its optical absorption technology provides reagent-free monitoring of suspended matter, with automatic temperature compensation and self-cleaning functionality where included in the selected configuration. The analog-output version supports connection to compatible PLCs, process controllers and data acquisition systems for direct measurement signal integration. It is suitable for sludge monitoring, wastewater process control and industrial effluent management.
| Item | Specification |
| Model | SS312-01-ANALOG-3 |
| Measurement principle | Optical absorption |
| Range options | 0–20000 / 0–5000 / 0–1000 / 0–200 mg/L; select one |
| Measurement error | ±5% FS; depends on sludge homogeneity; temperature: 0.5 °C |
| Resolution | 0.1 mg/L; temperature: 0.1 °C |
| Response time | ≤30 s |
| Supply voltage | DC 12–30 V; 0–10 V output requires DC 24 V |
| Power consumption | 1.8 W normal; 5.1 W during self-cleaning |
| Analog output | 4–20 mA / 0–5 V / 0–10 V; select one |
| Probe operating temperature | 0–40 °C |
| Housing environment | −40 to +60 °C; 0–95% RH, non-condensing |
| Ingress protection | Probe: IP68; transmitter housing: IP65 |
| Flow velocity | <3 m/s |
| Probe pressure limit | <0.1 MPa |
| Probe cable | 5 m standard; customizable |
| Housing material | Corrosion-resistant plastic and stainless steel |
| Maintenance / calibration interval | 3 months recommended |
| Self-cleaning system service life | 18 months; dynamic seal replacement required after continuous use |
| Housing dimensions | 117 × 87 × 43 mm maximum |
| Probe dimensions / thread | 247 mm dimension shown; 227 mm body dimension; Ø50 mm; NPT 3/4 |