Suspended Solids Transmitter
SS312-01-WIFI-2
悬浮物变送器
产品亮点
• Integrated self-cleaning system reduces biofouling.
• Modulated light reduces visible-light interference.
• Automatic temperature compensation.
• 2 s acquisition; configurable upload interval.
• LAN and WAN communication; DNS support.
• Modulated light reduces visible-light interference.
• Automatic temperature compensation.
• 2 s acquisition; configurable upload interval.
• LAN and WAN communication; DNS support.
产品概述
The SpeSense SS312-01-WIFI Suspended Solids Transmitter is designed for online suspended solids monitoring in water and wastewater applications. Its optical absorption sensing approach measures suspended matter without routine chemical reagents, supporting continuous observation of water quality conditions. Wi-Fi connectivity provides wireless data transmission to compatible monitoring systems, making the instrument suitable for connected treatment facilities, industrial water monitoring installations and local environmental monitoring networks. It supports suspended solids data collection for wastewater treatment, sludge management and process supervision.
| Item | Specification |
| Model | SS312-01-WIFI-2 |
| Measurement principle | Optical absorption |
| Range options | 0–20000 / 0–5000 / 0–1000 / 0–200 mg/L; select one |
| Measurement error | ±5% FS; depends on sludge homogeneity |
| Resolution | 0.1 mg/L |
| Response time | ≤30 s |
| Supply voltage | DC 12–30 V |
| Power consumption | 1.4 W normal; 4.7 W during self-cleaning |
| Data upload | Wi-Fi; IEEE 802.11b/g/n |
| Probe operating temperature | 0–40 °C |
| Housing environment | −40 to +60 °C; 0–95% RH, non-condensing |
| Ingress protection | Probe: IP68; transmitter housing: IP65 |
| Flow velocity | <3 m/s |
| Probe pressure limit | <0.1 MPa |
| Data acquisition interval | 2 s |
| Data upload interval | 10 s default; configurable from 1 to 65535 s |
| Probe cable | 5 m standard; customizable |
| Housing material | Corrosion-resistant plastic and stainless steel |
| Maintenance / calibration interval | 3 months recommended |
| Self-cleaning system service life | 18 months; dynamic seal replacement required after continuous use |
| Housing dimensions | 117 × 87 × 43 mm maximum |
| Probe dimensions / thread | 247 mm dimension shown; 227 mm body dimension; Ø50 mm; NPT 3/4 |
| Wi-Fi security | WEP / WPA-PSK / WPA2-PSK; WEP / TKIP / AES encryption |