greenhouse
SS209-01
4G智能温室环境监测仪
产品亮点
● No field communication cabling or transmission-distance limitation.
● Configurable upper and lower alarms with multi-parameter calibration.
● Online real-time data and battery-level monitoring.
● Default low-power operation with automatic data recovery upload.
● Configurable upper and lower alarms with multi-parameter calibration.
● Online real-time data and battery-level monitoring.
● Default low-power operation with automatic data recovery upload.
产品概述
The SpeSense SS209-01 4G Smart Greenhouse Environment Monitor is designed for remote monitoring of greenhouse climate and soil conditions in precision agriculture applications. It integrates air temperature, humidity, illuminance, atmospheric pressure and CO₂ monitoring, with support for up to seven external RS485 soil sensor channels. Built-in battery power, an integrated solar panel and 4G cellular data transmission enable autonomous field monitoring without dedicated communication cabling. Remote data access, configurable alarm thresholds and calibration functions make the SS209-01 suitable for smart greenhouses, agricultural research, crop management and distributed farm monitoring systems.
| Item | Specification |
| Power Supply | Built-in battery with integrated solar panel |
| Communication Interface | 4G cellular network |
| Data Upload | 20 min by default; 10 min temperature step check with immediate trigger upload; step function can be disabled |
| Air Temperature Range | -40 to +120 °C |
| Air Temperature Resolution | 0.1 °C |
| Air Humidity Range | 0 to 99% RH |
| Air Humidity Resolution | 0.1% RH |
| External Soil Sensors | Compatible with RS485 soil sensors; up to 7 configurable channels |
| Illuminance Range | 0 to 200,000 lux |
| Illuminance Resolution | 1 lux |
| Illuminance Accuracy | ±7% at 25 °C |
| CO2 Range | 0 to 5000 ppm; effective range 400 to 5000 ppm |
| CO2 Resolution | 1 ppm |
| CO2 Accuracy | ±(50 ppm + 3% F.S.) at 25 °C |
| Atmospheric Pressure Range | 0 to 120 kPa |
| Atmospheric Pressure Resolution | 0.1 kPa |
| Atmospheric Pressure Accuracy | ±0.15 kPa at 25 °C and 101 kPa |
| Transmitter Circuit Environment | -20 to +60 °C; 0 to 95% RH, non-condensing |
| Data Storage | 65,000 records |